Sensorineural Loss

فهرست عناوین اصلی در این پاورپوینت

فهرست عناوین اصلی در این پاورپوینت

● AUDIOLOGY
The Secrets Behind the Squiggles

Dave Pothier
St Mary’s, October 2003
● Ear examination
● Striking the fork
● Rinne’s Test
● Rinne interpretation
● Weber
● Weber – interpretation
● Simple free field testing
● Concepts
● What this tells you
● Pure Tone Audiometry
● Important concept…
● But, to confuse even more…
● And, we all know BC is not as good as AC, don’t we?
● Calibration!
● Those mysterious markings
● Legends for PTA’s
● Air conduction
● How they do it (briefly)
● Normal PTA
● Conductive Loss
● Sensorineural Loss
● Mixed Loss
● Masking
● Interaural attenuation
● PTA limitations
● Tympanometry
● Normal tympanogram (Type A)
● Other Type A tympanograms
● Flat tympanogram (Type B)
● Negative tympanogram (Type C)
● Final Thought


نوع زبان: انگلیسی حجم: 1.13 مگا بایت
نوع فایل: اسلاید پاورپوینت تعداد اسلایدها: 42 صفحه
سطح مطلب: نامشخص پسوند فایل: ppt
گروه موضوعی: زمان استخراج مطلب: 2019/06/15 09:14:38

لینک دانلود رایگان لینک دانلود کمکی

اسلایدهای پاورپوینت مرتبط در پایین صفحه

عبارات مهم استفاده شده در این مطلب

عبارات مهم استفاده شده در این مطلب

db, loss, test, rinne, hearing, tone, –, normal, type, ‘s, ear,

توجه: این مطلب در تاریخ 2019/06/15 09:14:38 به صورت خودکار از فضای وب آشکار توسط موتور جستجوی پاورپوینت جمع آوری شده است و در صورت اعلام عدم رضایت تهیه کننده ی آن، طبق قوانین سایت از روی وب گاه حذف خواهد شد. این مطلب از وب سایت زیر استخراج شده است و مسئولیت انتشار آن با منبع اصلی است.

http://www.entformedstudents.co.uk/files/ppts/audiology.ppt

در صورتی که محتوای فایل ارائه شده با عنوان مطلب سازگار نبود یا مطلب مذکور خلاف قوانین کشور بود لطفا در بخش دیدگاه (در پایین صفحه) به ما اطلاع دهید تا بعد از بررسی در کوتاه ترین زمان نسبت به حدف با اصلاح آن اقدام نماییم. جهت جستجوی پاورپوینت های بیشتر بر روی اینجا کلیک کنید.

عبارات پرتکرار و مهم در این اسلاید عبارتند از: db, loss, test, rinne, hearing, tone, –, normal, type, ‘s, ear,

مشاهده محتوای متنیِ این اسلاید ppt

مشاهده محتوای متنیِ این اسلاید ppt

audiology the secrets behind the squiggles dave pothier st mary’s october ۲ ۳ ear examination make sure ear is not occluded no other physical abnormalities put audiological tests into context ‘interesting’ technique tuning fork tests rinne’s test weber’s test striking the fork on bony prominence not on hard surface gives better single tone without overtones rinne’s test purpose compare ac to bc how strike tuning fork place tf alternately on mastoid process and eam rinne interpretation normal positive rinne – louder at eam ac bc abnormal negative rinne – louder on mastoid process positive rinne – bilateral snhl rinne interpretation true negative rinne conductive hearing loss bc ac false negative rinne severe s n loss on test side tone heard on contralateral side rinne interpretation if rinne negative masking is essential types tragal rub baranay noise box weber purpose conductive vs. snhl in unilateral losses how strike fork place midline of head incisors vertex forehead weber interpretation normal midline sensation of hearing equal hearing both sides of same type equal loss of same type abnormal – tone louder in on one side conductive loss – tone louder on affected side snhl – tone louder on contralateral side simple free field testing by ‘bedside’ good adjunct to pta helpful with children too young for pta fairly sensitive give some idea of significance of hearing loss concepts turn patients head to side so cannot see examiner s mouth apply tragal rub masking to non test ear furthest away whisper at arms length then increase loudness of voice in increments patient to repeat numbers words what this tells you can hear whisper at arm’s length – normal hearing can hear normal voice at arm’s length – mild moderate loss can hear loud voice at arm’s length moderate severe loss can only hear loud voice close up profound loss pure tone audiometry setup physics ac bc masking pure tone audiometry sound has ۲ components frequency pitch cf. wavelength hz khz intensity loudness cf. amplitude db setup physics pure tone audiometry the decibel sound intensity spl measured in decibels log of intensity of sound nb.. a logarithmic scale ۲ db is ۱ times db ۴ db is ۱ times ۲ db ۶ db is ۱ times louder than db setup physics very confusing… db used as measures of spl are different to db’s used as measure of hearing level pure tone audiometry setup physics important concept… a hearing level of db is an arbitrary level of hearing of a given spl iowa state fair allegedly in ۱۹۳۵ ۱ young women had their hearing measured this established the normal hearing levels for pure tone audiometry db threshold but to confuse even more… the cochlear does not hear all sounds equally at all frequencies and we all know bc is not as good as ac don’t we so why does a normal pta look like this calibration the audiometer accounts for the different hearing levels at different frequencies as well as the ‘natural’ reverse a b gap. clever thing those mysterious markings legends for pta’s air conduction bone conduction how they do it briefly otoscopy explanation best ear start with ac on best ear start at ۱ hz at ۶ db down by ۱ db until no response then up by ۵db until reponse ۳ out of ۵ up and down frequencies same for bone normal pta conductive loss sensorineural loss mixed loss masking used to prevent non test ear hearing stimulus presented to test ear interaural attenuation bone assumed to be db but probably nearer ۴ ۶db air assumed to be greater the ۴ db but varies between patients masking used to eliminate this confounding factor pta limitations pta in not always a ‘gold standard’ and infallible limited by patient audiologist and equipment beware on nohl try to supplement other simple tests tympanometry tympanometry measure of compliance of tm at varying pressures in eam normal tympanogram type a peak at dpa best movement of drum when no extra pressure on either side of tm other type a tympanograms peak at dpa but unusually high amplitude ossicular disruption peak at dpa but unusually low amplitude stapes fixation flat tympanogram type b no peak no best tm movement at any pressure flat tympanogram type b when tymp is flat usually means ۱ of ۳ things artefact fluid in me perforation look at eam vol. if large perf if normal fluid negative tympanogram type c peak at dpa best movement of drum when no negative pressure in eam thus middle ear pressure must be atmospheric negative tympanogram type c can be further divided into c۱ – peak between and ۲ dapa c۲ – peak less than ۲ dapa final thought tests are not infallible they are only as good as those taking administering and interpreting them… …

کلمات کلیدی پرکاربرد در این اسلاید پاورپوینت: db, loss, test, rinne, hearing, tone, –, normal, type, ‘s, ear,

این فایل پاورپوینت شامل 42 اسلاید و به زبان انگلیسی و حجم آن 1.13 مگا بایت است. نوع قالب فایل ppt بوده که با این لینک قابل دانلود است. این مطلب برگرفته از سایت زیر است و مسئولیت انتشار آن با منبع اصلی می باشد که در تاریخ 2019/06/15 09:14:38 استخراج شده است.

http://www.entformedstudents.co.uk/files/ppts/audiology.ppt

  • جهت آموزش های پاورپوینت بر روی اینجا کلیک کنید.
  • جهت دانلود رایگان قالب های حرفه ای پاورپوینت بر روی اینجا کلیک کنید.

رفتن به مشاهده اسلاید در بالای صفحه


پاسخی بگذارید

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *